gps wг. Минск, 4-й пер. Кольцова, 51-318

mail w1nektis@mail.ru

mail winfo@nektis.by

Датчик идентификации Keyence BL-1350HA

COM_VIRTUEMART_PRODUCT_NOSTOCK
ModelBL-1350HA
TypeHigh-resolution side type
TypeReading directionSide
Scanning methodSingle
LaserLight sourceVisible red semiconductor laser (660 nm wavelength)
Control output85 µW
Pulse duration112 µs
Laser classClass 2 Laser Product (IEC60825-1, FDA (CDRH) Part1040.10*1)
ReadingSupported codesCODE 39, ITF, Industrial 2of5, Standard 2of5, COOP 2of5, NW-7 (Codabar), CODE 128, GS1-128, CODE 93, EAN/UPC, GS1 DataBar
Number of readable digits74 digits (148 digits with CODE 128 start character C)
Readable bar width0.08 mm to
Reading distance40 to 250 mm*2 (0.5 mm narrow bar width)
Focal point65 mm
Largest readable label width201 mm*2 (175 mm distance, 0.5 mm narrow bar width)
PCS0.4 or more
Scanning rate500 to 1,300 scans/second
I/O specificationsInput terminalsNumber of inputsTwo (IN1, IN2)
Input formatnon-voltage input (contact or solid-state)
Output terminalsNumber of outputsFour (OUT1 through OUT4)
OutputNPN open collector
Rated load24 VDC, 30 mA
Leakage current (at OFF)0.1 mA or less
Residual voltage (at ON)0.5 V or less
Serial interfaceCommunication methodConforms to EIA, RS-232C
Communication speed600, 1,200, 2,400, 4,800, 9,600, 19,200, 31,250, 38,400, 57,600, 115,200 bps
Synchronisation between the transmitter and receiverAsynchronous
Data bit length7/8 bits
Stop bit length1/2 bits
Parity checkNone/Even/Odd
RatingPower voltage5 VDC ±5 %
Voltage consumption400 mA or less
Environmental resistanceEnclosure ratingIP65
Ambient light10,000 lux (sunlight), 6,000 lux (Incandescent lamp)
Operating environmentNo dust or corrosive gas present
Ambient temperature0 to +45 °C
Storage temperature-20 to +60 °C
Relative humidity35 to 85 % RH (No condensation)
Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
WeightApprox. 130 g
*1 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
*2 Specifications for 500-scan/second operation
Use the Limited Power Source defined in UL/IEC60950-1 to comply with UL/IEC60950-1.
Internal body settings are written in the internal memory area (can be rewritten 100,000 times).